Enclosure Thermal Management: Sealing vs Heat

Enclosure Thermal Management: Sealing and Heat Are Opposites

Every vent you add to cool a cabinet is a hole in its IP rating. That is the whole problem, and it is why thermal management has to be decided at the drawing stage rather than solved with a fan drilled in afterwards. This page is about the trade-off, and about which cooling route suits which cabinet.

Fulei Metal builds the enclosure around your thermal requirement — wall thickness and material for conduction, vent and filter positions for natural convection, fan mounts and plenums for forced air, and the mounting for heat exchangers — in a 2,500 m² plant in Ningbo, China, since 2016.

Why the problem exists

Electronics make heat. Heat raises internal temperature, which shortens component life and eventually causes failure. The fix is to get the heat out. But an outdoor or washdown cabinet has to be sealed to keep water and dust out — and sealing stops the air movement that carries heat away.

So the design question is not “how do we cool it” but “how much heat has to leave, and what is the least sealing we can give up to let it.”

First: how much heat are we talking about

Internal dissipationTypical equipmentUsual route
Under ~50 WTerminals, small PLC, a contactor or twoNatural conduction through the wall; no vent needed
50–200 WMid-size control cabinet, drives, several breakersNatural convection with a filtered vent, or a single fan
200–600 WBattery cabinets, inverter cabinets, dense device panelsForced air with filtered intake, or a closed-loop heat exchanger
Over 600 WHigh-density power equipmentAir conditioner or liquid cooling — outside what we build

If you can give us the dissipation figure, the ambient temperature range and the target internal temperature, we can tell you which route the cabinet needs. If you cannot, send the device list and we will estimate it with you.

The four cooling routes

RouteHow it worksIP impactTrade-off
ConductionHeat travels through the wall to the outside surfaceNone — the cabinet stays sealedLimited to low dissipation; aluminium conducts far better than steel
Natural convectionWarm air rises out of a high vent, cool air in lowDrops to IP54 unless the vents are filtered and labyrinthedFilter needs cleaning; dust bypasses simple mesh
Forced airFan pushes air through, usually with a filtered intakeIP54 typical; IP55 achievable with a good filterFan is a wear item; positive pressure helps keep dust out
Closed-loop heat exchangerInternal and external air circuits exchange heat through a core; no air crossesIP rating preservedCost and mounting space; needs both internal and external airflow

Choosing the route

SituationRecommendationWhy
Indoor control room, low dissipationConduction, or a louvred ventNo IP requirement to protect; simplest and cheapest
Outdoor, moderate dissipationForced air with a filtered intake, or a heat exchangerRain and dust have to stay out; a filter is the compromise
Outdoor, high dissipation, must hold IP66Closed-loop heat exchangerThe only route that keeps a high IP rating at high load
Battery or PCS cabinetForced ventilation, designed as a systemBattery off-gassing and thermal runaway make this a safety question, not a comfort one
Weight-sensitiveAluminium body with conductionAluminium moves roughly five times the heat of steel for the same geometry

Where the heat actually goes wrong

1. The vent is on the wrong wall. A vent low on a door in an outdoor cabinet collects rain. Intake low and outlet high works indoors; outdoors, the inlet needs to be shielded, baffled, or moved to a face that is not exposed.

2. The filter is forgotten in the drawing. A fan mount with no filter housing turns the cabinet into a dust collector within months. The filter needs a position, a retention method and a replacement route — all drawn.

3. Internal layout ignores convection. A device mounted low in a sealed box with no air path above it will cook regardless of the wall material. Component placement is a thermal decision, and it is usually made by whoever lays out the panel.

4. Solar gain on the roof. A dark roof in direct sun can add more heat than the electronics make. A light-coloured or reflective finish, a shade roof, or a double-skin roof with an air gap solves it, and it is a drawing decision.

What we build, and what we do not

We buildWe do not
Enclosure walls, roofs and doors to the thermal designFormal thermal simulation reports
Vent openings, louvres, baffles and filter housingsFan, heat exchanger or air conditioner supply
Fan mounts, plenums and airflow dividersComponent-level thermal design
Heat exchanger mounting frames and cutoutsCertification of the thermal performance
Material and finish selection for solar gain—

We do not issue thermal simulation or performance certification. What we do is build the mechanical envelope your thermal design specifies, with the openings, mounts and airflow paths in the right places, and hold the dimensions so the equipment you select fits.

What to put on the drawing

  • Internal dissipation in watts, or the device list it comes from
  • Ambient temperature range at the installation site, including solar exposure
  • Target internal temperature, and whether it is a limit or a guideline
  • Cooling route — conduction, vent, fan or heat exchanger — and the equipment model if known
  • Filter specification and replacement route, if forced air is used
  • IP rating, stated with the cooling route, because the two trade against each other
  • Roof treatment — colour, shade, or double skin

Related reading

Frequently asked questions

Can you keep IP66 with a fan inside?

Not with a simple through-wall fan. A fan that moves air across the wall is an open path. The routes that hold IP66 are a closed-loop heat exchanger, or a sealed cabinet relying on conduction with enough external surface area. We will tell you which your dissipation figure needs.

Do you supply the heat exchanger or the fan?

No. We build the mounting frame, the cutouts and the airflow path to the model you specify. If you have not selected one yet, send the dissipation and ambient figures and we will tell you the class of equipment the cabinet needs to accommodate.

Aluminium or steel for a hot cabinet?

Aluminium, if weight and budget allow. It conducts heat away from the internals far better than steel, which matters most at low dissipation where you are relying on conduction rather than airflow. Steel is cheaper and stiffer, and works fine when you have forced air doing the work.

Can you tell us how hot the inside will get?

Not as a certified figure. We can tell you what the mechanical design supports — surface area, material, vent area, airflow path — and we will build to the thermal design you or your engineer specifies. Formal thermal analysis is outside what we do.

What lead times apply?

Simple samples 3–7 days. Complex first articles 15–20 days. Production batches 25–35 days, quoted after drawing review. Freight is quoted separately to your port.

Do you hold ISO 9001 certification?

Our quality system is documented to ISO 9001. We do not hold a third-party ISO 9001 certificate and do not claim one. Third-party audit evidence is available under NDA: TÜV Rheinland MIC-ASI243729 and Bureau Veritas MIC-ASR263630.

Send the heat figures

Send the internal dissipation, the ambient range and the IP rating you need. Those three decide the cooling route, and the cooling route decides the enclosure design. Getting them on the first enquiry saves a revision cycle later.

Scroll to Top